375 research outputs found

    Implantable device monitoring versus usual care for managing individuals with heart failure

    Full text link
    © 2019 The Cochrane Collaboration. Published by John Wiley & Sons, Ltd. This is a protocol for a Cochrane Review (Intervention). The objectives are as follows: To assess the effects of using implantable device monitoring as an additional management tool for individuals with heart failure, compared with usual care alone

    Not all systematic reviews are systematic: A meta-review of the quality of systematic reviews for non-invasive remote monitoring in heart failure

    Full text link
    We carried out a critical appraisal and synthesis of the systematic reviews and meta-analyses of remote monitoring for heart failure. A comprehensive literature search identified 65 relevant publications from 3333 citations. Seventeen studies fulfilled the inclusion and exclusion criteria. Seven (41%) systematic reviews pooled results for meta-analysis. Eight (47%) considered all non-invasive remote monitoring strategies. Five (29%) focused on telemonitoring. Four (24%) included both non-invasive and invasive technologies. The reviews were appraised by two independent reviewers for their quality and risk of bias using the AMSTAR tool. According to the AMSTAR criteria, ten (58%) systematic reviews were of poor methodological quality. In the high quality reviews, the relative risk of mortality in patients who received remote monitoring ranged from 0.53 to 0.88. The high quality reviews also reported that remote monitoring reduced the relative risk of all-cause (0.52 to 0.96) and heart failure-related hospitalizations (0.72 to 0.79) and, as a consequence, healthcare costs. However, further research is required before considering widespread implementation of remote monitoring. The subset of the heart failure population that derives the most benefit from intensive monitoring, the best technology, and the optimum duration of monitoring, all need to be identified. © The Author(s) 2013

    Potential role for clinical calibration to increase engagement with and application of home telemonitoring: a report from the HeartCycle programme

    Get PDF
    Aims: There is a need for alternative strategies that might avoid recurrent admissions in patients with heart failure. Home Telemonitoring (HTM) to monitor patient’s symptoms from a distance may be useful. This study attempts to assess changes in HTM vital signs in response to daily life activities (variations in medication, salt intake, exercise and stress) and to stablish which variations affect weight, blood pressure (BP) and heart rate (HR). Methods and results: We assessed 76 patients with heart failure (mean age 76 ± 10.8 years, 75% male, mainly in NYHA class II/III and from ischaemic etiology cause). Patients were given a calendar of interventions scheduling activities approximately twice-a-week before measuring their vital signs. Eating salty food or a large meal were the activities that had a significant impact on weight gain (+0.3 kg; p<0.001 and p=0.006, respectively). Exercise and skipping a dose of medication other than diuretics increased heart rate (+3 bpm, p=0.001 and almost +2 bpm, p=0.016, respectively). Conclusions: Our HTM system was able to detect small changes in vital signs related to these activities. Further studies should assess if providing such a schedule of activities might be useful for patient education and could improve long-term adherence to recommended lifestyle changes

    The effects of aetiology on outcome in patients treated with cardiac resynchronization therapy in the CARE-HF trial

    Get PDF
    Aims: Cardiac dyssynchrony is common in patients with heart failure, whether or not they have ischaemic heart disease (IHD). The effect of the underlying cause of cardiac dysfunction on the response to cardiac resynchronization therapy (CRT) is unknown. This issue was addressed using data from the CARE-HF trial.Methods and resultsPatients (n = 813) were grouped by heart failure aetiology (IHD n = 339 vs. non-IHD n = 473), and the primary composite (all-cause mortality or unplanned hospitalization for a major cardiovascular event) and principal secondary (all-cause mortality) endpoints analysed. Heart failure severity and the degree of dyssynchrony were compared between the groups by analysing baseline clinical and echocardiographic variables. Patients with IHD were more likely to be in NYHA class IV (7.5 vs. 4.0; P = 0.03) and to have higher NT-proBNP levels (2182 vs. 1725 pg/L), indicating more advanced heart failure. The degree of dyssynchrony was more pronounced in patients without IHD (assessed using mean QRS duration, interventricular mechanical delay, and aorta-pulmonary pre-ejection time). Left ventricular ejection fraction and left ventricular end-systolic volume improved to a lesser extent in the IHD group (4.53 vs. 8.50 and -35.68 vs. -58.52 cm 3). Despite these differences, CRT improved all-cause mortality, NYHA class, and hospitalization rates to a similar extent in patients with or without IHD.ConclusionThe benefits of CRT in patients with or without IHD were similar in relative terms in the CARE-HF study but as patients with IHD had a worse prognosis, the benefit in absolute terms may be greater

    A novel approach to improve cardiac performance: cardiac myosin activators

    Get PDF
    Decreased systolic function is a central factor in the pathogenesis of heart failure, yet there are no safe medical therapies to improve cardiac function in patients. Currently available inotropes, such as dobutamine and milrinone, increase cardiac contractility at the expense of increased intracellular concentrations of calcium and cAMP, contributing to increased heart rate, hypotension, arrhythmias, and mortality. These adverse effects are inextricably linked to their inotropic mechanism of action. A new class of pharmacologic agents, cardiac myosin activators, directly targets the kinetics of the myosin head. In vitro studies have demonstrated that these agents increase the rate of effective myosin cross-bridge formation, increasing the duration and amount of myocyte contraction, and inhibit non-productive consumption of ATP, potentially improving myocyte energy utilization, with no effect on intracellular calcium or cAMP. Animal models have shown that this novel mechanism increases the systolic ejection time, resulting in improved stroke volume, fractional shortening, and hemodynamics with no effect on myocardial oxygen demand, culminating in significant increases in cardiac efficiency. A first-in-human study in healthy volunteers with the lead cardiac myosin activator, CK-1827452, as well as preliminary results from a study in patients with stable chronic heart failure, have extended these findings to humans, demonstrating significant increases in systolic ejection time, fractional shortening, stroke volume, and cardiac output. These studies suggest that cardiac myosin activators offer the promise of a safe and effective treatment for heart failure. A program of clinical studies are being planned to test whether CK-1827452 will fulfill that promise

    Early prediction of cardiac resynchronization therapy response by non-invasive electrocardiogram markers

    Full text link
    [EN] Cardiac resynchronization therapy (CRT) is an effective treatment for those patients with severe heart failure. Regrettably, there are about one third of CRT "non-responders", i.e. patients who have undergone this form of device therapy but do not respond to it, which adversely affects the utility and cost-effectiveness of CRT. In this paper, we assess the ability of a novel surface ECG marker to predict CRT response. We performed a retrospective exploratory study of the ECG previous to CRT implantation in 43 consecutive patients with ischemic (17) or non-ischemic (26) cardiomyopathy. We extracted the QRST complexes (consisting of the QRS complex, the S-T segment, and the T wave) and obtained a measure of their energy by means of spectral analysis. This ECG marker showed statistically significant lower values for non-responder patients and, joint with the duration of QRS complexes (the current gold-standard to predict CRT response), the following performances: 86% accuracy, 88% sensitivity, and 80% specificity. In this manner, the proposed ECG marker may help clinicians to predict positive response to CRT in a non-invasive way, in order to minimize unsuccessful procedures.This work was supported by MINECO under grants MTM2013-43540-P and MTM2016-76647-P.Ortigosa, N.; Pérez-Roselló, V.; Donoso, V.; Osca Asensi, J.; Martínez-Dolz, L.; Fernández Rosell, C.; Galbis Verdu, A. (2018). Early prediction of cardiac resynchronization therapy response by non-invasive electrocardiogram markers. Medical & Biological Engineering & Computing. 56(4):611-621. https://doi.org/10.1007/s11517-017-1711-1S611621564Boggiatto P, Fernández C, Galbis A (2009) A group representation related to the stockwell transform. Indiana University Mathematics Journal 58(5):2277–2296Brignole M, Auricchio A, Baron-Esquivias G, Bordachar P, Boriani G et al (2013) 2013 ESC guidelines on cardiac pacing and cardiac resynchronization therapy. Europace 15:1070–1118Brown RA, Lauzon ML, Frayne R (2010) A general description of linear time-frequency transforms and formulation of a fast, invertible transform that samples the continuous s-transform spectrum nonredundantly. IEEE Trans Signal Process 58(1): 281–290Carità P, Corrado E, Pontone G, Curnis A, Bontempi L et al (2016) Non-responders to cardiac resynchronization therapy: insights from multimodality imaging and electrocardiography. A brief review. Int J Cardiol 225:402–407Cazeau S, Leclercq C, Lavergne T, Walker S, Varma C, Linde C et al (2001) Effects of multisite biventricular pacing in patients with heart failure and intraventricular conduction delay. N Engl J Med 344:873–880Chang CC, Lin CJ (2011) LIBSVM: a library for support vector machines. ACM Trans Intell Syst Technol 2(3):27:1–27:27Chawla NV, Bowyer KW, Hall LO, Kegelmeyer WP (2002) SMOTE: synthetic minority over-sampling technique. J Artif Intell Res 16(1):321–357Cleland JGF, Abraham WT, Linde C, Gold MR, Young J et al (2013) An individual patient meta-analysis of five randomized trials assessing the effects of cardiac resyn- chronization therapy on morbidity and mortality in patients with symptomatic heart failure. Eur Heart Journal 34(46):3547–3556Cleland JGF, Calvert MJ, Verboven Y, Freemantle N (2009) Effects of cardiac resynchronization therapy on long-term quality of life: an analysis from the Cardiac Resynchronisation-Heart Failure (CARE-HF) study. Am Heart J 157:457–466Cleland JGF, Freemantle N, Erdmann E, Gras D, Kappenberger L et al (2012) Long-term mortality with cardiac resynchronization therapy in the Cardiac Resynchronization-Heart Failure (CARE-HF) trial. Eur J Heart Fail 14:628–634Egoavil CA, Ho RT, Greenspon AJ, Pavri BB (2005) Cardiac resynchronization therapy in patients with right bundle branch block: analysis of pooled data from the MIRACLE and Contak CD trials. Heart Rhythm 2(6):611–615Engels EB, Mafi-Rad M, van Stipdonk AM, Vernooy K, Prinzen FW (2016) Why QRS duration should be replaced by better measures of electrical activation to improve patient selection for cardiac resynchronization therapy. J Cardiovasc Transl Res 9(4):257–265Engels EB, Végh EM, Van Deursen CJ, Vernooy K, Singh JP, Prinzen FW (2015) T-wave area predicts response to cardiac resynchronization therapy in patients with left bundle branch block. J Cardiovasc Electrophysiol 26(2):176–183Eschalier R, Ploux S, Ritter P, Haïssaguerre M, Ellenbogen K, Bordachar P (2015) Nonspecific intraventricular conduction delay: definitions, prognosis, and implications for cardiac resynchronization therapy. Heart Rhythm 12(5):1071–1079Goldenberg I, Kutyifa V, Klein HU, Cannom DS, Brown MW et al (2014) Survival with cardiac-resynchronization therapy in mild heart failure. N Engl J Med 370:1694–1701He H, Bai Y, Garcia EA, Li S (2008) ADASYN: adaptive synthetic sampling approach for imbalanced learning. In: International joint conference on neural networks, pp 1322–1328Jacobsson J, Borgguist R, Reitan C, Ghafoori E, Chatterjee NA et al (2016) Usefulness of the sum absolute QRST integral to predict outcomes in patients receiving cardiac resynchronization therapy. J Cardiovasc Electrophysiol 118(3):389–395McMurray JJ (2010) Clinical practice. Systolic heart failure. N Engl J Med 3623:228–238Meyer CR, Keiser HN (1977) Electrocardiogram baseline noise estimation and removal using cubic splines and state-space computation techniques. Comput Biomed Res 10:459–470Ortigosa N, Giménez VM (2014) Raw data extraction from electrocardiograms with portable document format. Comput Meth Programs Biomed 113(1):284–289Ortigosa N, Osca J, Jiménez R, Rodríguez Y, Fernández C, Galbis A (2016) Predictive analysis of cardiac resynchronization therapy response by means of the ECG. 2016 Comput Cardio 43:753–756. https://doi.org/10.22489/CinC.2016.218-415Ponikowski P, Voors AA, Anker S, Bueno H, Cleland JG, Coats AJ et al (2016) 2016 ESC guidelines for the diagnosis and treatment of acute and chronic heart failure: the task force for the diagnosis and treatment of acute and chronic heart failure of the European Society of Cardiology (ESC). Developed with the special contribution of the Heart Failure Association (HFA) of the ESC. Eur J Heart Fail 18(8):891–975Rad MM, Wijntjens GW, Engels EB, Blaauw Y, Luermans JG et al (2016) Vectorcardiographic QRS area identifies delayed left ventricular lateral wall activation determined by electroanatomic mapping in candidates for cardiac resynchronization therapy. Heart Rhythm 13(1):217–225Shanks M, Delgado V, Bax JJ (2016) Cardiac resynchronization therapy in non-ischemic cardiomyopathy. Journal of Atrial Fibrillation 8(5):47–52Singh JP, Fan D, Heist EK, Alabiad CR, Taub C et al (2006) Left ventricular lead electrical delay predicts response to cardiac resynchronization therapy. Heart Rhythm 3(11):1285–1292Sohaib SM, Finegold JA, Nijjer SS, Hossain R, Linde C et al (2015) Opportunity to increase life span in narrow QRS cardiac resynchronization therapy recipients by deactivating ventricular pacing: evidence from randomized controlled trials. JACC Heart Fail 3:327–336Stockwell RG, Mansinha L, Lowe RP (1996) Localization of the complex spectrum: the S transform. IEEE Trans Signal Process 44(4):998–1001Tang ASL, Wells GA, Talajic M, Arnold MO, Sheldon R et al (2010) Cardiac-resynchronization therapy for mild-to-moderate heart failure. N Engl J Med 363:2385–2395Tereshchenko LG, Cheng A, Park J, Wold N, Meyer TE, Gold MR et al (2015) Novel measure of electrical dyssynchrony predicts response in cardiac resynchronization therapy: results from the SMART-AV trial. Heart Rhythm 12(2):2402–2410van Deursen CJ, Vernooy K, Dudink E, Bergfeldt L, Crijns HJ et al (2015) Vectorcardiographic QRS area as a novel predictor of response to cardiac resynchronization therapy. J Electrocardiol 48(1):45–52Wang TJ (2003) Natural history of asymptomatic left ventricular systolic dysfunction in the community. Circulation 108:977–982Woods B, Hawkins N, Mealing S, Sutton A, Abraham WT et al (2015) Individual patient data network meta-analysis of mortality effects of implantable cardiac devices. Heart 101:1800–1806Ypenburg C, van Bommel RJ, Borleffs CJ, Bleeker GB, Boersma E et al (2009) Long-term prognosis after cardiac resynchronization therapy is related to the extent of left ventricular reverse remodeling at midterm follow-up. J Am Coll Cardiol 53(6):483–490Yu CM, Hayes DL (2013) Cardiac resynchronization therapy: state of the art 2013. Eur Heart J 34:1396–140

    Prevalence of scarred and dysfunctional myocardium in patients with heart failure of ischaemic origin: a cardiovascular magnetic resonance study

    Get PDF
    BACKGROUND: Cardiovascular magnetic resonance (CMR) with late gadolinium enhancement (LGE) can provide unique data on the transmural extent of scar/viability. We assessed the prevalence of dysfunctional myocardium, including partial thickness scar, which could contribute to left ventricular contractile dysfunction in patients with heart failure and ischaemic heart disease who denied angina symptoms. METHODS: We invited patients with ischaemic heart disease and a left ventricular ejection fraction < 50% by echocardiography to have LGE CMR. Myocardial contractility and transmural extent of scar were assessed using a 17-segment model. RESULTS: The median age of the 193 patients enrolled was 70 (interquartile range: 63-76) years and 167 (87%) were men. Of 3281 myocardial segments assessed, 1759 (54%) were dysfunctional, of which 581 (33%) showed no scar, 623 (35%) had scar affecting ≤50% of wall thickness and 555 (32%) had scar affecting > 50% of wall thickness. Of 1522 segments with normal contractile function, only 98 (6%) had evidence of scar on CMR. Overall, 182 (94%) patients had ≥1 and 107 (55%) patients had ≥5 segments with contractile dysfunction that had no scar or ≤50% transmural scar suggesting viability. CONCLUSIONS: In this cohort of patients with left ventricular systolic dysfunction and ischaemic heart disease, about half of all segments had contractile dysfunction but only one third of these had > 50% of the wall thickness affected by scar, suggesting that most dysfunctional segments could improve in response to an appropriate intervention

    Sequential biventricular pacing improves regional contractility, longitudinal function and dyssynchrony in patients with heart failure and prolonged QRS

    Get PDF
    <p>Abstract</p> <p>Aims</p> <p>Biventricular pacing (BiP) is an effective treatment in systolic heart failure (HF) patients with prolonged QRS. However, approximately 35% of the patients receiving BiP are classified as non-responders. The aim of this study is to evaluate the acute effects of VV-optimization on systolic heart function.</p> <p>Methods</p> <p>Twenty-one HF patients aged 72 (46-88) years, QRS 154 (120-190) ms, were studied with echocardiography, Tissue Doppler Imaging (TDI) and 3D-echo the first day after receiving a BiP device. TDI was performed; during simultaneous pacing (LV-lead pacing 4 ms before the RV-lead) and during sequential pacing (LV 20 and 40 ms before RV and RV 20 and 40 ms before LV-lead pacing). Systolic heart function was studied by tissue tracking (TT) for longitudinal function and systolic maximal velocity (SMV) for regional contractility and signs of dyssynchrony assessed by time-delays standard deviation of aortic valve opening to SMV, AVO-SMV/SD and tissue synchronization imaging (TSI).</p> <p>Results</p> <p>The TT mean value preoperatively was 4,2 ± 1,5 and increased at simultaneous pacing to 5,0 ± 1,2 mm (p < 0,05), and at best VV-interval to 5,4 ± 1,2 (p < 0,001). Simultaneous pacing achieved better TT distance compared with preoperative in 16 patients (76%). However, it was still higher after VV-optimization in 12 patients 57%. Corresponding figures for SMV were 3,0 ± 0,7, 3,5 ± 0,8 (p < 0,01), and 3,6 ± 0,8 (p < 0,001). Also dyssynchrony improved.</p> <p>Conclusions</p> <p>VV-optimization in the acute phase improves systolic heart function more than simultaneous BiP pacing. Long-term effects should be evaluated in prospective randomized trials.</p

    The EuroHeart Failure survey programme—a survey on the quality of care among patients with heart failure in Europe Part 1: patient characteristics and diagnosis

    Get PDF
    The European Society of Cardiology (ESC) has published guidelines for the investigation of patients with suspected heart failure and, if the diagnosis is proven, their subsequent management. Hospitalisation provides a key point of care at which time diagnosis and treatment may be refined to improve outcome for a group of patients with a high morbidity and mortality. However, little international data exists to describe the features and management of such patients. Accordingly, the EuroHeart Failure survey was conducted to ascertain if appropriate tests were being performed with which to confirm or refute a diagnosis of heart failure and how this influenced subsequent management. Methods The survey screened consecutive deaths and discharges during 2000-2001 predominantly from medical wards over a 6-week period in 115 hospitals from 24 countries belonging to the ESC, to identify patients with known or suspected heart failure. Results A total of 46,788 deaths and discharges were screened from which 11,327 (24%) patients were enrolled with suspected or confirmed heart failure. Forty-seven percent of those enrolled were women. Fifty-one percent of women and 30% of men were aged >75 years. Eighty-three percent of patients had a diagnosis of heart failure made on or prior to the index admission. Heart failure was the principal reason for admission in 40%. The great majority of patients (>90%) had had an ECG, chest X-ray, haemoglobin and electrolytes measured as recommended in ESC guidelines, but only 66% had ever had an echocardiogram. Left ventricular ejection fraction had been measured in 57% of men and 41% of women, usually by echocardiography (84%) and was <40% in 51% of men but only in 28% of women. Forty-five percent of women and 22% of men were reported to have normal left ventricular systolic function by qualitative echocardiographic assessment. A substantial proportion of patients had alternative explanations for heart failure other than left ventricular systolic or diastolic dysfunction, including valve disease. Within 12 weeks of discharge, 24% of patients had been readmitted. A total of 1408 of 10,434 (13.5%) patients died between admission and 12 weeks follow-up. Conclusions Known or suspected heart failure comprises a large proportion of admissions to medical wards and such patients are at high risk of early readmission and death. Many of the basic investigations recommended by the ESC were usually carried out, although it is not clear whether this was by design or part of a general routine for all patients being admitted regardless of diagnosis. The investigation most specific for patients with suspected heart failure (echocardiography) was performed less frequently, suggesting that the diagnosis of heart failure is still relatively neglected. Most men but a minority of women who underwent investigation of cardiac function had evidence of moderate or severe left ventricular dysfunction, the main target of current advances in the treatment of heart failure. Considerable diagnostic uncertainty remains for many patients with suspected heart failure, even after echocardiography, which must be resolved in order to target existing and new therapies and services effectively. (C) 2003 Published by Elsevier Science Ltd on behalf of The European Society of Cardiology